Systems · Services

Full-stack fire & security engineering.

Design, installation, commissioning, integration, 24/7 monitoring and annual maintenance of fire alarm systems, FM200 & NOVEC 1230 gas suppression, sprinkler & hydrant networks, IP CCTV, access control and intrusion detection — under one roof, by one PEC-licensed team. Trusted across Karachi, Lahore, Islamabad and every province of Pakistan.

Fire alarm, suppression and security systems engineering
01 / Detection

Fire Detection & Alarm Systems

Addressable and conventional fire-alarm architectures engineered for Pakistani climates — humidity, dust, voltage fluctuation. NFPA 72 compliant, stamped by PEC-licensed engineers.

  • Honeywell Notifier, Hochiki, Siemens Cerberus, Edwards
  • Multi-sensor, photoelectric, ionization, heat, beam, aspirating (VESDA)
  • Loop isolators, short-circuit protection, graphical annunciation
  • BMS, PA/VA and HVAC integration on BACnet/Modbus
Fire alarm control panel
Standard
NFPA 72
Typical scale
50 – 2,500 devices
Warranty
2 yr incl. AMC
Handover
Stamped drawing pack
Fire sprinkler head
Standard
NFPA 13 / 20 / 24
Pumps
Diesel + Electric + Jockey
Heads
Tyco · Viking · Reliable
Commissioning
3rd-party witnessed
02 / Suppression — Water

Sprinkler & Hydrant Systems

Wet, dry, pre-action and deluge sprinklers; hose reels, landing valves, fire hydrants, and dedicated fire-water networks. Hydraulically calculated; pressure-tested; witnessed.

  • Pre-action interlocks for sensitive spaces
  • Foam-water systems for dye / hydrocarbon hazards
  • Complete pump room with controllers
  • Full hydraulic calculations submitted with BOQ
03 / Suppression — Gas

Clean Agent Gas Suppression

FM200 (HFC-227ea), Novec 1230, CO₂, Inergen and NOVEC-hybrid systems for server rooms, telecom shelters, MCC panels, archives, and heritage interiors. No residue. No collateral.

  • NFPA 2001 design discharge (≤10 s)
  • Door-fan room integrity testing on handover
  • VESDA aspirating ultra-early warning detection
  • Annual refill & pressure-test programme
FM-200 clean agent cylinders
Agents
FM200 · Novec · CO₂
Design time
≤10 seconds discharge
Standard
NFPA 2001
Integrity test
Door-fan witnessed
CCTV surveillance camera
Cameras
4K · AI · thermal
VMS
Genetec · Milestone · Hikcentral
Access
Face · biometric · turnstile
ANPR
Gates · parking · tolls
04 / Physical Security

CCTV, Access Control & Intrusion Detection

4K IP CCTV cameras (Hikvision, Dahua, Bosch, Axis), NVR & VMS platforms, AI analytics (loitering, crowd, PPE, ANPR), biometric and face-recognition access control, perimeter intrusion detection, panic alarms — fully integrated with fire alarm and monitored 24/7 from our Karachi command centre.

05 / Integration

Integrated Command Centre (PSIM)

Fuse fire, video, access, intrusion, BMS and SCADA into a single operator dashboard. Automated SOPs. Role-based permissions. Audit-grade event logs. IoT-ready via MQTT/BACnet/Modbus.

  • Cause-and-effect matrices automated
  • Multi-site federation
  • Mobile operator app
  • SLA dashboards for management
Fire
CCTV
Access
Intrusion
BMS
SCADA
↓ Single pane of glass
ZikTech Command Platform
Beyond Installation

Audit. Train. Maintain.

Third-Party Fire & Security Audits

Independent walkthrough + report against NFPA / TAC / Pakistan Fire Safety Rules 2023. Delivered in 10 working days.

Emergency-Response Training

On-site drills, fire-warden certification, evacuation-plan design — in English & Urdu, for all staff levels.

Annual Maintenance Contracts

Quarterly testing, spares stocking, cylinder refills, software updates, logged reporting — on a fixed-price retainer.

How We Work

Five steps from risk to resilience.

01
Site survey

Free walkthrough & preliminary risk brief.

02
Engineering design

Stamped drawings, cause-and-effect matrix, BOQ.

03
Supply & install

OEM-direct supply. In-house installation crews.

04
Commission & test

Third-party witnessed tests + integrity validation.

05
Monitor & maintain

24/7 monitoring, AMC, quarterly reporting.

Not sure which system you need?

Our engineers will walk your site and recommend the minimum system that actually meets code — no upselling.